Table 2 DFT calculated elastic stiffness tensor coefficients.
From: Domain topology and domain switching kinetics in a hybrid improper ferroelectric
Coefficient | C 11 | C 12 | C 13 | C 33 | C 44 | C 66 |
|---|---|---|---|---|---|---|
Value | 315 | 77.6 | 98.0 | 297 | 81.6 | 83.1 |
From: Domain topology and domain switching kinetics in a hybrid improper ferroelectric
Coefficient | C 11 | C 12 | C 13 | C 33 | C 44 | C 66 |
|---|---|---|---|---|---|---|
Value | 315 | 77.6 | 98.0 | 297 | 81.6 | 83.1 |