Table 1 The properties of magnets used in in vitro and in vivo experiments.
From: Magnetic forces enable controlled drug delivery by disrupting endothelial cell-cell junctions
Experiment | Dimension of magnet | Residue induction (T) |
|---|---|---|
In vitro static cell culture | ||
Cellular uptake | Cylinder (d × l=1/10″ × 1/4″) | 1.32 |
Magnetic pulling | Block (l × w × h=1″ × 1/4″ × 1/4″) | 1.48 |
Microfluidic channels | Block (l × w × h=1″ × 1/2″ × 1/2″) | 1.48 |
In vivo lateral tail vein | Block (l × w × h=1″ × 1/4″ × 1/4″) | 1.48 |