Abstract
“Smart Materials” are materials that change their shape, color, or size in response to an externally applied stimulus. While smart materials have already made a tremendous impact on our lives through their applications in liquid crystal displays, headphones, fuel injection systems, flexible cell phone antennas, and many other commercial products, they also have the potential to help many pediatric patients. This review focuses on with the present and potential applications of shape memory alloys, piezoelectric materials, and the relatively newer class of materials called magnetostrictive and ferromagnetic shape memory alloys in the design of pediatric cardiovascular devices.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
Abbreviations
- ASD:
-
atrial septal defect
- FSMA:
-
ferromagnetic shape memory alloys
- MFIS:
-
magnetic field induced strain
- NiMnGa:
-
Nickel Manganese Gallium
- NiTi:
-
nitinol
- PDA:
-
patent ductus arteriosus
- PFO:
-
patent foramen ovale
- PZT:
-
lead zirconate titanate (Pb(ZrTi)O3)
- VSD:
-
ventricular septal defect
References
Armitage DA, Grant DM 2003 Characterisation of surface-modified nickel titanium alloys. Mater Sci Eng 349: 89–97
Armitage DA, Parker TL, Grant DM 2003 Biocompatibility and hemocompatibility of surface-modified NiTi alloys. J Biomed Mater Res A 66: 129–137
Ryhanen J, Niemi E, Serlo W, Niemela E, Sandvik P, Pernu H, Salo T 1997 Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res 35: 451–457
Trepanier C, Leung T, Tabrizian M, Yahia L, Bienvenu J, Tanguay J, Piron D, Bilodeau L 1999 Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents. J Biomed Mater Res 48: 165–171
Weaver DJ, Veldhuizen AG, Sanders MM, Schakenraad JM, van Horn JR 1997 Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy. Biomaterials 18: 1115–1120
Tepe G, Wendel HP, Khorchidi S, Schmehl J, Wiskirchen J, Pusich B, Claussen CD, Duda SH 2002 Thrombogenicity of various endovascular stent types: an in vitro evaluation. J Vasc Interv Radiol 13: 1029–1035
Thierry B, Merhi Y, Bilodeau L, Trépanier C, Tabrizian M 2002 Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model. Biomaterials 23: 2997–3005
Rocher P, El Medawar L, Hornez JC, Traisnel M, Breme J, Hildenbrand HF 2004 Biocorrosion and cytocompatibility assessment of NiTi shape memory alloys. Scr Mater 50: 255–260
Shabalovskaya SA 2002 Surface, corrosion and biocompatibility aspects of nitinol as an implant. Biomed Mater Eng 12: 69–109
Dundar Y, Hill RA, Bakhai A, Dickson R, Walley T 2004 Angioplasty and stents in coronary artery disease: a systematic review and meta-analysis. Scand Cardiovasc J 38: 200–210
Rabe K, Sievert H 2004 Carotid artery stenting. J Interv Cardiol 17: 417–426
Cheatham JP 2001 Stenting of coarctation of the aorta. Catheter Cardiovasc Interv 54: 112–125
Thanopoulos BV, Rigby ML, Karanasios E, Stefanadis C, Blom N, Ottenkamp J, Zarayelyan A 2007 Transcatheter closure of perimembranous ventricular septal defects in infants and children using the amplatzer perimembranous ventricular septal defect occluder. Am J Cardiol 99: 984–989
Pass RH, Hijazi Z, Hsu DT, Lewis V, Hellenbrand WE 2004 Multicenter USA amplatzer patent ductus arteriosus occlusion device trial: initial and one-year results. J Am Coll Cardiol 44: 513–519
Du ZD, Hijazi ZM, Kleinman CS, Silverman NH, Larntz K, Amplatzer Investigators 2002 Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. J Am Coll Cardiol 39: 1836–1844
Chessa M, Carminati M, Cao QL, Butera G, Giusti S, Bini RM, Hijazi ZM 2002 Transcatheter closure of congenital and acquired muscular ventricular septal defects using the amplatzer device. J Invasive Cardiol 14: 322–327
Hong TE, Thaler D, Brorson J, Heitschmidt M, Hijazi ZM, Amplatzer PFO Investigators 2003 Transcatheter closure of patent foramen ovale associated with paradoxical embolism using the Amplatzer PFO occluder: initial and intermediate-term results of the US multicenter clinical trial. Catheter Cardiovasc Interv 60: 524–528
Chan KC, Godman MJ, Walsh K, Wilson N, Redington A, Gibbs JL 1999 Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (amplatzer septal occluder): multicentre UK experience. Heart 82: 300–306
Lorber A, Gazit AZ, Khoury A, Schwartz Y, Freudental F 2003 Percutaneous transaortic occlusion of patent ductus arteriosus using a new versatile angiographic and delivery catheter. Pediatr Cardiol 24: 482–483
Busch JD, Johnson AD, Lee CH, Stevenson DA 1990 Shape-memory properties in Ni-Ti sputter-deposited film. J Appl Phys 68: 6224–6228
Sekiguchi Y, Funami K, Funakubo H 1983 Deposition of NiTi shape memory alloy thin film by vacuum evaporation. Proceedings of 32nd Meeting of Japan Society of Materials, 65–67.
Makino E, Uenoyama M, Shibata T 1998 Flash evaporation of TiNi shape memory thin film for microactuators. Sensor Actuat A 71: 187–192
Lehnert T, Tixier S, Boni P, Gotthardt R 1999 A new fabrication process for Ni–Ti shape memory thin films. Mater Sci Eng A 273– 275: 713–716
Ikuta K, Hayashi M, Matsuura T, Fujishiro H 1994 An investigation of micro structures, sensors, actuators, machines and robotic systems. Proceedings of the IEEE Workshop Micro Electro Mechanical Systems, Oiso, Japan, pp 355–360.
Ming H Wu 2001 Fabrication of nitinol materials and components. Proceedings of the International Conference on Shape Memory and Superelastic Technologies, Kunming, China, pp 285–292.
Ho K, Carman GP 2000 Sputter deposition of NiTi thin film shape memory alloy using a heated target. Thin Solid Films 370: 18–29
Stepan LL, Levi DL, Carman GP 2005 A thin film nitinol heart valve. J Biomech Eng 127: 915–918
Gewillig M, Boshoff DE, Dens J, Mertens L, Benson LN 2004 Stenting the neonatal arterial duct in duct-dependent pulmonary circulation: new techniques, better results. J Am Coll Cardiol 43: 107–112
Ullakko K, Huang JK, Kantner C, Kokorin VV, O'Handley RC 1996 Large magnetic-field-inducted strains in Ni2MnGa signal crystals. Appl Phys Lett 69: 1966–1968
Murray SJ, Marioni M, Allen SM, O'Handley RC, Lograsso TA 2000 6% magnetic-field-induced strain by twin-boundary motion in ferromagnetic Ni-Mn-Ga. Appl Phys Lett 77: 886–888
Sozinov A, Likhachev AA, Lanska N, Ullakko K 2002 Giant magnetic-field-induced strain in NiMnGa seven-layered martenistic phase. Appl Phys Lett 80: 1746–1748
Sozinov A, Likhachev AA, Ullakko K 2002 Crystal structures and magnetic anisotropy properties of Ni-Mn-Ga martensitic phases with giant magnetic-field-induced strain. IEEE Trans Magn 38: 2814–2816
Gans E, Henry D, Carman GP 2004 Reduction in required magnetic field to induce twin-boundary motion in ferromagnetic shape memory alloys. J Appl Phys 95: 6965
Gans E, Carman GP 2006 Cyclic actuation of Ni–Mn–Ga composites. J Appl Phys 99: 084905
Prabhu SD 2007 Altered left ventricular-arterial coupling precedes pump dysfunction in early heart failure. Heart Vessels 22: 170–177
Krishnamoorthy VK, Sengupta PP, Gentile F, Khandheria BK 2007 History of echocardiography and its future applications in medicine. Crit Care Med 35: S309–S313
Hall LT, Maple JL, Agzatian J, Abbot D 2000 Sensor system for heart sound biomonitor. Microelectron J 31: 583–592
Lanning C, Shandas R 2003 Development and validation of implantable sensors for monitoring function of prosthetic heart valves: in vitro studies. Med Biol Eng Comput 41: 416–424
Elle OJ, Halvorsen S, Gulbrandsen MG, Aurdal L, Bakken A, Samset E, Dugstad H, Fosse E 2005 Early recognition of regional cardiac ischemia using a 3-axis accelerometer sensor. Physiol Meas 26: 429–440
Jang LS, Kan WH 2007 Peristaltic piezoelectric micropump system for biomedical applications. Biomed Microdevices 9: 619–626
Doll A, Wischke M, Schrag HJ, Geipel A, Goldschmidtboeing F, Woias P 2007 Characterization of active silicon microvalves with piezoelectric membrane actuators. Microelectron Eng 84: 1202–1206
Geipel A, Doll A, Jantscheff P, Esser N, Massing U, Woias P, Goldschmidtboeing F 2007 A novel two-stage backpressure-independent micropump: modeling and characterization. J Micromech Microeng 17: 949–959
Williams MJ Jr, Welkowitz W, Fich S, Molony DA, Jaron D, Kantrowitz A 1975 The design of a piezoelectric heart assist device. IEEE Trans Biomed Eng 22: 40–46
Siess T, Nix C, Menzler F 2001 From a lab type to a product: a retrospective view on impella's assist technology. Artif Organs 25: 414–421
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Levi, D., Kusnezov, N. & Carman, G. Smart Materials Applications for Pediatric Cardiovascular Devices. Pediatr Res 63, 552–558 (2008). https://doi.org/10.1203/PDR.0b013e31816a9d18
Received:
Accepted:
Issue date:
DOI: https://doi.org/10.1203/PDR.0b013e31816a9d18
This article is cited by
-
Application of an arched, Ni–Ti shape-memory connector in repairing distal tibiofibular syndesmosis ligament injury
BMC Musculoskeletal Disorders (2022)
-
Smart advanced responsive materials, synthesis methods and classifications: from Lab to applications
Journal of Polymer Research (2021)
-
A Review on Additive Manufacturing of Shape-Memory Materials for Biomedical Applications
JOM (2020)
-
Evaluation of NaOH pre-treatment on the corrosion behavior and surface characteristics of hydroxyapatite coated NiTi alloy
Applied Physics A (2020)
-
Fabrication and Characterization of Freestanding NiTi Based Thin Film Materials for Shape Memory Micro-actuator Applications
Shape Memory and Superelasticity (2019)