Table 12 Error analysis of dimension restoration of the Main Hall of Huayan Temple based on Y1, Y2 and Y3
Width | Depth | ||||||||
---|---|---|---|---|---|---|---|---|---|
Central room | Secondary room | Third room | Side corridor | Central room | Secondary room | Third room | Front porch | Back porch | |
Surveying data (unit: mm) | 6000 | 5400 | 2660 | 1790 | 6025 | 2600 | 2750 | 3580 | 1775 |
Dimension in yingzao chi (unit: Y1) | 15.17 | 13.66 | 6.73 | 4.53 | 15.24 | 6.58 | 6.95 | 9.05 | 4.49 |
Adjusted dimension (unit: Y1) | 15.25 | 13.75 | 6.75 | 4.50 | 15.25 | 6.50 | 7.00 | 9.00 | 4.50 |
Error (Y1) | 0.53% | 0.66% | 0.23% | 0.70% | 0.07% | 1.25% | 0.72% | 0.55% | 0.22% |
Dimension in yingzao chi (unit: Y2) | 15.94 | 14.34 | 7.07 | 4.75 | 16.00 | 6.91 | 7.30 | 9.51 | 4.71 |
Adjusted dimension (unit: Y2) | 16.00 | 14.25 | 7.00 | 4.75 | 16.00 | 7.00 | 7.25 | 9.50 | 4.75 |
Error (Y2) | 0.38% | 0.63% | 1.03% | 0.00% | 0.00% | 1.26% | 0.68% | 0.11% | 0.85% |
Dimension in yingzao chi (unit: Y3) | 16.87 | 15.19 | 7.48 | 5.03 | 16.94 | 7.31 | 7.73 | 10.07 | 4.99 |
Adjusted dimension (unit: Y3) | 17.00 | 15.25 | 7.50 | 5.00 | 17.00 | 7.25 | 7.75 | 10.00 | 5.00 |
Error (Y3) | 0.77% | 0.39% | 0.27% | 0.60% | 0.35% | 0.82% | 0.26% | 0.70% | 0.20% |