Table 9 Error analysis of dimension restoration of the Main Hall of Huayan Temple based on Y4 and Y5
Width | Depth | ||||||||
---|---|---|---|---|---|---|---|---|---|
Central room | Secondary room | Third room | Side corridor | Central room | Secondary room | Third room | Front porch | Back porch | |
Surveying data (unit: mm) | 6000 | 5400 | 2660 | 1790 | 6025 | 2600 | 2750 | 3580 | 1775 |
Dimension in yingzao chi (unit: Y4) | 17.92 | 16.12 | 7.94 | 5.34 | 17.99 | 7.76 | 8.21 | 10.69 | 5.30 |
Adjusted dimension (unit: Y4) | 18.00 | 16.25 | 8.00 | 5.25 | 18.00 | 7.75 | 8.25 | 10.75 | 5.25 |
Error (Y4) | 0.47% | 0.81% | 0.76% | 2.25% | 0.06% | 0.13% | 0.49% | 0.56% | 0.95% |
Dimension in yingzao chi (unit: Y5) | 18.54 | 16.69 | 8.22 | 5.53 | 18.62 | 8.03 | 8.50 | 11.06 | 5.49 |
Adjusted dimension (unit: Y5) | 18.50 | 16.75 | 8.25 | 5.50 | 18.50 | 8.00 | 8.50 | 11.00 | 5.50 |
Error (Y5) | 0.22% | 0.36% | 0.36% | 0.54% | 0.64% | 0.37% | 0.00% | 0.54% | 0.18% |