Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Article
  • Published:

Targeted neonatal echocardiography (TNE) consult service in a large tertiary perinatal center in Canada

Abstract

Objective

To describe the utilization and study the factors associated with the impact on clinical management of a new TNE consultation service in a perinatal center.

Methods

This retrospective cohort study included all neonates who underwent TNE consultation at the neonatal unit of Mount Sinai Hospital in Toronto, Canada (November 2011 and July 2015). The consults that had “impact” were defined as those that led to a TNE suggested change in the clinical management within 6 h of its recommendation. Logistic regression analysis was performed to identify factors associated with a change in clinical management following the consultation.

Results

A total of 553 consults were performed for 268 infants (gestational age: 27 ± 4 weeks and age at initial consult: 16 (5, 34) days). Patent ductus arteriosus (PDA, 61%), suspected pulmonary hypertension (PH, 27%), and systemic hypotension (SH, 9%) were the common indications. The average consultations increased from 9 in 2012–2013 to 20 per month in 2014–2015. Forty eight percent of consults had an impact on clinical management (PDA scans: 38%, PH: 58%, and SH: 81%, p < 0.01 between all). Male gender (adjusted odds ratio (95% confidence interval): 1.9 (1.0, 3.5); p = 0.04), mechanical ventilation (2.43 (1.2, 4.9); p = 0.01), and scans for PH (7.1 (2.2, 23.2); p < 0.01) and SH (2.6 (1.1, 6.5); p = 0.03) were independently associated with the impact on clinical management. TNE consults identified all incidental cases of major structural defects (n = 4), and six out of ten minor diagnoses.

Conclusions

TNE consult service demonstrated an increasing utilization and a significant impact on clinical management over time especially for non-PDA indications and in situations of high-illness severity. Although, all major cardiac defects were identified, some minor congenital defects were missed by TNEs.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Sehgal A, McNamara PJ. Does point-of-care functional echocardiography enhance cardiovascular care in the NICU? J Perinatol. 2008;28:729–35.

    Article  CAS  Google Scholar 

  2. El-Khuffash AF, McNamara PJ. Neonatologist-performed functional echocardiography in the neonatal intensive care unit. Semin Fetal Neonatal Med. 2011;16:50–60.

    Article  Google Scholar 

  3. Jain A, McNamara PJ, Ng E, El-Khuffash A. The use of targeted neonatal echocardiography to confirm placement of peripherally inserted central catheters in neonates. Am J Perinatol. 2012;29:101–6.

    Article  Google Scholar 

  4. Mukerji A, Diambomba Y, Lee SK, Jain A. Use of targeted neonatal echocardiography and focused cardiac sonography in tertiary neonatal intensive care units: time to embrace it? J Ultrasound Med. 2016;35:1579–91.

    Article  Google Scholar 

  5. Mertens L, Seri I, Marek J, Arlettaz R, Barker P, McNamara P, et al. Targeted neonatal echocardiography in the neonatal intensive care unit: practice guidelines and recommendations for training. Writing group of the American Society of Echocardiography (ASE) in collaboration with the European Association of Echocardiography (EAE) and the Association for European Pediatric Cardiologists (AEPC). J Am Soc Echocardiogr. 2011;24:1057–78.

    Article  Google Scholar 

  6. Singh Y, Gupta S, Groves AM, Gandhi A, Thomson J, Qureshi S, et al. Expert consensus statement ‘Neonatologist-performed Echocardiography (NoPE)’-training and accreditation in UK. Eur J Pediatr. 2016;175:281–7.

    Article  Google Scholar 

  7. Mertens L, Seri I, Marek J, Arlettaz R, Barker P, McNamara P, et al. Targeted neonatal echocardiography in the neonatal intensive care unit: practice guidelines and recommendations for training. Eur J Echocardiogr. 2011;12:715–36.

    Article  Google Scholar 

  8. El-Khuffash A, Herbozo C, Jain A, Lapointe A, McNamara PJ. Targeted neonatal echocardiography (TnECHO) service in a Canadian neonatal intensive care unit: a 4-year experience. J Perinatol. 2013;33:687–90.

    Article  CAS  Google Scholar 

  9. Harabor A, Soraisham AS. Utility of targeted neonatal echocardiography in the management of neonatal illness. J Ultrasound Med. 2015;34:1259–63.

    Article  Google Scholar 

  10. Finan E, Sehgal A, Khuffash AE, McNamara PJ. Targeted neonatal echocardiography services: need for standardized training and quality assurance. J Ultrasound Med. 2014;33:1833–41.

    Article  Google Scholar 

  11. Evans N. Echocardiography on neonatal intensive care units in Australia and New Zealand. J Paediatr Child Health. 2000;36:169–71.

    Article  CAS  Google Scholar 

  12. Corredera A, Rodriguez MJ, Arevalo P, Llorente B, Moro M, Arruza L. [Functional echocardiography in neonatal intensive care: 1 year experience in a unit in Spain]. An Pediatr . 2014;81:167–73.

    Article  CAS  Google Scholar 

  13. Moss S, Kitchiner DJ, Yoxall CW, Subhedar NV. Evaluation of echocardiography on the neonatal unit. Arch Dis Child Fetal Neonatal Ed. 2003;88:F287–9. discussionF90-1.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Amish Jain.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Papadhima, I., Louis, D., Purna, J. et al. Targeted neonatal echocardiography (TNE) consult service in a large tertiary perinatal center in Canada. J Perinatol 38, 1039–1045 (2018). https://doi.org/10.1038/s41372-018-0130-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue date:

  • DOI: https://doi.org/10.1038/s41372-018-0130-y

This article is cited by

Search

Quick links