Fig. 6: Experimental analysis of the device as a sensing unit.
From: Organic-inorganic hybrid piezotronic bipolar junction transistor for pressure sensing

Transient response of the PBJT with respect to the (a) collector-emitter voltage and (b) collector-emitter current. c \(\triangle V/{V}_{0}\) and (d) \(\triangle I/{I}_{0}\) versus applied pressure as for the PBJT and a p-n junction diode. e Sensitivity of the PBJT based on the voltage and current. f Peak current/voltage signal-to-noise-ratio. g Comparison among state-of-the-art devices and the PBJT in terms of sensitivity and showcasing superiority of the proposed piezotronic bipolar junction transistor