Table 1 Characteristics of the 43 datasets of the ENIGMA Autism Spectrum Disorder working group that were used in this study.

From: Subtly altered topological asymmetry of brain structural covariance networks in autism spectrum disorder across 43 datasets from the ENIGMA consortium

Dataset no.

Dataset name

N total

N cases (M/F)

N controls (M/F)

Mean age (min, max)

Scanner type

Field strength

1

ABIDE_CALTECH

31

13/1

13/4

29.1 (17.5, 56.2)

Siemens Trio

3 T

2

ABIDE_LEUVEN_2

35

12/3

15/5

14.2 (12.1, 16.9)

Philips Interna

3 T

3

ABIDE_MAX_MUN

51

21/3

24/3

26.5 (7, 58)

Siemens Verio

3 T

4

ABIDE_NYU

184

68/10

81/25

15.3 (6.5, 39.1)

Siemens Allegra

3 T

5

ABIDE_OLIN

36

17/3

14/2

16.8 (10, 24)

Siemens Allegra

3 T

6

ABIDE_PITT

58

26/5

23/4

19.2 (9.3, 35.2)

Siemens Allegra

3 T

7

ABIDE_SBL

30

15/0

15/0

34.4 (20, 64)

Philips Interna

3 T

8

ABIDE_SDSU

37

14/1

16/6

15.0 (8.7, 37.7)

GE MR750

3 T

9

ABIDE_STANFORD

40

16/4

16/4

10.0 (7.5, 12.9)

GR Signa

3 T

10

ABIDE_TCD

55

24/1

30/0

16.7 (9.3, 25.9)

Philips Achieva

3 T

11

ABIDE_UM_1

126

48/14

41/23

12.8 (8.1, 20.9)

GE Signa

3 T

12

ABIDE_UM_2

31

14/1

15/1

15.3 (11.1, 26.8)

GE Signa

3 T

13

ABIDE_USM

100

59/0

41/0

21.3 (8.2, 50.2)

Siemens Trio

3 T

14

ABIDE_YALE

55

20/8

19/8

12.7 (7, 17.8)

Siemens Magnetom

3 T

15

ABIDEII-BNI

57

28/0

29/0

38.1 (18, 6)

Philips Ingenia

3 T

16

ABIDEII-EMC

41

18/2

19/2

8.3 (6.4, 10.7)

GE MR750

3 T

17

ABIDEII-ETH

31

11/0

20/0

22.9 (13.8, 30.7)

Philips Achieva

3 T

18

ABIDEII-GU

98

39/8

26/25

10.7 (8.1, 13.9)

Siemens TriTim

3 T

19

ABIDEII-IP

52

14/7

9/22

20.7 (6.1, 46.6)

Siemens TriTim

1.5 T

20

ABIDEII-IU

39

15/4

15/5

24.4 (17, 54)

Philips Achieva

3 T

21

ABIDEII-KKI

199

35/15

94/55

10.3 (8.0, 13.0)

Philips Achieva

3 T

22

ABIDEII-NYU_1

72

38/4

28/2

10.1 (5.2, 34.8)

Siemens Allegra

3 T

23

ABIDEII-OHSU

92

29/7

27/29

11.0 (7, 15)

Siemens Skyra

3 T

24

ABIDEII-OILH

39

12/1

17/9

23.5 (18, 31)

Siemens TriTim

3 T

25

ABIDEII-SDSU

57

26/7

22/2

13.0 (7.4, 18)

GE MR750

3 T

26

ABIDEII-TCD

41

19/0

22/0

15.4 (10, 20)

Philips Achieva

3 T

27

ABIDEII-USM

32

15/2

12/3

21.4 (9.1, 38.9)

Siemens TriTim

3 T

28

BRC

44

17/0

27/0

14.8 (10, 18)

GE Signa HDx

3 T

29

Barcelona

52

29/2

20/1

12.0 (7.3, 17.1)

Siemens Trio

3 T

30

Dresden

45

18/3

20/4

35.3 (21.1, 56.8)

Siemens Trio

3 T

31

FAIR

81

33/6

27/15

11.5 (7.8, 15.9)

Siemens Magnetom

3 T

32

FSM

80

20/20

20/20

4.1 (1.8, 6)

GE Signa

1.5 T

33

MRC

137

67/0

70/0

27.0 (18, 45)

GE Signa HDx

3 T

34

PITT_1

56

11/3

34/8

16.3 (8, 36)

Siemens Allegra

3 T

35

PITT_2

89

38/6

39/6

17.0 (8, 36)

Siemens Allegra

3 T

36

ParelladaHGGM

66

33/2

30/1

12.5 (7, 18)

Philips Intera

1.5 T

37

TCD_2

27

10/0

17/0

16.9 (12.7, 24.8)

Philips Achieva

3 T

38

TORONTO_1

177

70/20

45/42

11.8 (3.3, 20.8)

Siemens Trio

3 T

39

TORONTO_2

192

99/41

28/24

11.0 (2.5, 21.7)

Siemens Trio

3 T

40

UMCU_1

57

25/3

27/2

14.3 (7.1, 24.7)

Philips

1.5 T

41

NIJMEGEN2

68

27/18

15/8

26.3 (18, 40)

Siemens Avanto

1.5 T

42

NIJMEGEN3

92

36/4

43/9

9.5 (6.1, 12.3)

Siemens Avanto

1.5 T

43

NIJMEGEN1

33

14/3

14/2

15.0 (12.3, 18.0)

Siemens Trio

3 T