Fig. 3: Spectrum at fixed density.
From: Quantum-dot assisted spectroscopy of degeneracy-lifted Landau levels in graphene

a dI/dV vs. −VSrc and B, graphene density fixed at nGr = 3.1 × 1012 cm−2. Dashed regions mark N = 0 and N = 1 spectral features which show evidence of degeneracy lifting. b Simulation modelling the data at a. μDot = 95 meV, dDot = 0.85 nm. Spectral features are marked by index pair: Injection/ejection level NI and ground state NG. Compressible and incompressible regimes are marked at the negative bias. c Energies of the split peaks of the N = 1 feature. d Energy difference of the features in c. Dashed line corresponds to g = 36. e Energies of the split peaks of the N = 0 feature. f Energy difference of the peaks in e. Blue: Valley split. Red: Spin split. Overlay lines trace two different slopes, corresponding to g = 100 and g = 160, respectively.