Table 1 Cryo-EM data collection, refinement and validation statistics.

From: Structure of human RNA polymerase III

Data collection (0° Tilt)

     Voltage (kV)

300

     Electron exposure (e2)

44.1

     Defocus range (μm)

−1.0 to −3.0

     Pixel size (Å)

1.065

Data collection (30° Tilt)

     Voltage (kV)

300

     Electron exposure (e2)

37.8, 40.6

     Defocus range (μm)

−1.2 to −3.0

     Pixel size (Å)

1.065

Reconstruction (RELION)

     Initial particle images (no.)

172,678

     Final particle images (no.)

25,369

     Map resolution (Å)

4.0

     FSC threshold

(0.143-thr)

     Map sharpening B factor (Å2)

−116.839

Model composition

 

     Non-hydrogen atoms

34,636

     Protein residues

4369

Refinement (PHENIX)

 

     Map CC

0.53

R.m.s. deviations

 

     Bond lengths (Å)

0.016

     Bond angles (°)

1.086

Validation

 

     MolProbity score

2.74

     Clashscore (all-atom)

31.792

     Poor rotamers

0.0

Ramachandran plot

 

     Favoured (%)

78.66

     Allowed (%)

20.94

     Disallowed (%)

0.39