Table 1 List of instruments used to measure each heat metric and the solar reflectivity of the RP

From: Evidence-based guidance on reflective pavement for urban heat mitigation in Arizona

Instrument

Accuracy

Response Time

Height (m)

Heat metric

Statistical test

Stationary (S) or Mobile (M)

1–3 T-type Thermocouples (car)

±1.0 °C

<0.1 s

2.0 m

Tair

Mann-Whitney U test

M

Platinum Resistance Thermometer (MaRTy)

±0.2 °C at (23 °C);

±0.5 °C at

(−40/60 °C)

<22 s

1.7 m

Tair

descriptive

S

Apogee SI-111 Infrared Radiometer (car)

±0.2 °C at

(−10/65 °C);

±0.5 °C at

(−40/70 °C)

<1 s

0.10 m

Tsfc

Mann-Whitney U test

M

Downward facing Pyrgeometer – IR01 (MaRTy)

±2.4% on Tsfc on daily sum

<18 s

0.99 m

Tsfc

descriptive

S

3 NR01 Hukseflux 4-Component Net Radiometers oriented in 6 directions (MaRTy)

±2.4% on Tmrt on daily sum

<18 s

1.11 m

Tmrt

descriptive

S

ASD FieldSpec 4 Wide-Res Field Spectroradiometer

3 nm (VNIR)

30 nm (SWIR)

N/A

1.0 m

N/A

descriptive

S