Table 1 Specifications of all polystyrene microparticles

From: Nominally identical microplastic models differ greatly in their particle-cell interactions

Sample

Manufacturer

Product name

Product no.

Modification

Nominal diameter (µm)

Measured diameter (µm)

ζ (mV)

PY

Polysciences, Inc.

Polybead® Microspheres

17134-15

None

3.00

3.08 ± 0.2

−83.8 ± 0.3

MM

Micromod GmbH

micromer®

01-00-303

None

3

2.94 ± 0.02

−4.7 ± 0.3

MG

Microparticles GmbH

PS-Forschungspartikel

None

None

3.03

2.97 ± 0.11

−12.6 ± 0.3

KI

Kisker Biotech GmbH & Co.KG

Polystyrene microparticles

PPS-3.0

None

3

2.96 ± 0.03

−5.3 ± 0.5

ST

Spherotech, Inc.

none

PP-30-10

None

3.43

3.47 ± 0.26

−93.1 ± 1.1

TS

ThermoFisher Scientific, Inc.

Latex Microspheres

5300 A

None

2.8

2.84 ± 0.03

−13.7 ± 0.2

TJ

Tianjin BaseLine Chromatographic Technology

Unibead PS-Microspheres

6-1-0300

None

3.0

3.36 ± 0.07

−45.5 ± 0.7

PX

Phosphorex, Inc.

Polyspherex

11

None

3.246

3.13 ± 0.33

−7.5 ± 0.4

MM-SW2

Micromod GmbH

micromer®

01-00-303

Salt water incubation, 2 weeks

3

2.97 ± 0.17

−10.0 ± 0.7

MM-SW4

Micromod GmbH

micromer®

01-00-303

Salt water incubation, 4 weeks

3

3.03 ± 0.14

−7.2 ± 1.3

MM-FW2

Micromod GmbH

micromer®

01-00-303

Freshwater incubation, 2 weeks

3

2.88 ± 0.28

-9.2 ± 0.5

MM-FW4

Micromod GmbH

micromer®

01-00-303

Freshwater incubation, 4 weeks

3

2.96 ± 0.04

−16.0 ± 2.3

  1. Measured diameters were determined by scanning electron microscopy (see Supplementary Note 1, Supplementary Table 1). Values of measured diameter and ζ-potential represent mean ± standard deviation. For the measured diameter, n = 10 particles were analyzed per sample. The ζ-potential measurements were replicated n = 3 times.