Table 4 Data of burst tests
From: Limit state equation and failure pressure prediction model of pipeline with complex loading
literature Sources | test No. | diameter (mm) | grade | D/t | axial stress (MPa) | yield strength (MPa) | tensile Strength (MPa) |
---|---|---|---|---|---|---|---|
Paslay et al.53 | 13 | 88.9 | L80 | 14.5 | 348.79247 | 695.201 | 753.766 |
16 | 88.9 | L80 | 18.0 | 586.66283 | 695.201 | 753.766 | |
17 | 88.9 | L80 | 18.6 | 638.14491 | 695.201 | 753.766 | |
18 | 177.8 | K55 | 26.7 | 454.31971 | 465.764 | 737.23 | |
19 | 196.85 | Q125 | 18.1 | 884.73801 | 905.346 | 993.538 | |
Lasebikan et al.54a | 22 °C−1 | 8 | 125 |  | 450 | 969 | 1063 |
22 °C−2 | 450 | ||||||
22 °C−3 | 460 | ||||||
22 °C−4 | 550 | ||||||
22 °C−5 | 540 | ||||||
22 °C−6 | 650 | ||||||
22 °C−7 | 655 | ||||||
22 °C−8 | 665 | ||||||
22 °C−9 | 750 | ||||||
22 °C−10 | 751 | ||||||
22 °C−11 | 740 | ||||||
22 °C−12 | 750 | ||||||
90 °C−1 | 400 | 881 | 948 | ||||
90 °C−2 | 410 | ||||||
90 °C−3 | 410 | ||||||
90 °C−4 | 550 | ||||||
90 °C−5 | 551 | ||||||
90 °C−6 | 650 | ||||||
110 °C−1 | 400 | 851 | 935 | ||||
110 °C−2 | 400 | ||||||
110 °C−3 | 400 | ||||||
110 °C−4 | 550 | ||||||
110 °C−5 | 545 | ||||||
110 °C−6 | 550 | ||||||
160 °C−1 | 400 | 821 | 888 | ||||
160 °C−2 | 400 | ||||||
160 °C−3 | 550 | ||||||
160 °C−4 | 550 | ||||||
160 °C−5 | 650 |