Table 4 Data of burst tests

From: Limit state equation and failure pressure prediction model of pipeline with complex loading

literature Sources

test No.

diameter (mm)

grade

D/t

axial stress (MPa)

yield strength (MPa)

tensile Strength (MPa)

Paslay et al.53

13

88.9

L80

14.5

348.79247

695.201

753.766

16

88.9

L80

18.0

586.66283

695.201

753.766

17

88.9

L80

18.6

638.14491

695.201

753.766

18

177.8

K55

26.7

454.31971

465.764

737.23

19

196.85

Q125

18.1

884.73801

905.346

993.538

Lasebikan et al.54a

22 °C−1

8

125

 

450

969

1063

22 °C−2

450

22 °C−3

460

22 °C−4

550

22 °C−5

540

22 °C−6

650

22 °C−7

655

22 °C−8

665

22 °C−9

750

22 °C−10

751

22 °C−11

740

22 °C−12

750

90 °C−1

400

881

948

90 °C−2

410

90 °C−3

410

90 °C−4

550

90 °C−5

551

90 °C−6

650

110 °C−1

400

851

935

110 °C−2

400

110 °C−3

400

110 °C−4

550

110 °C−5

545

110 °C−6

550

160 °C−1

400

821

888

160 °C−2

400

160 °C−3

550

160 °C−4

550

160 °C−5

650

  1. aNote: Data were obtained from the reference literature’s charts; D and t represent the diameter and the wall thickness, respectively.