Fig. 5: Structural and hemocompatibility of anticoagulant supercapacitors. | Nature Communications

Fig. 5: Structural and hemocompatibility of anticoagulant supercapacitors.

From: An anticoagulant supercapacitor for implantable applications

Fig. 5

a Cross-section SEM of anticoagulant supercapacitor with all-in-one structure and element mapping of C, O, and S element, respectively; the biocompatibility and hemocompatibility of anticoagulant supercapacitor: b digital photographs of the growth of L929 cells at 24 and 48 h, respectively, c cell proliferation at different concentrations measured by cck-8 method, d the hemolysis rate (HR) (PC refers to a positive control (DI water), and NC refers to negative control (normal saline)), e anticoagulant performance, f platelets numbers, and g the SEM of platelet adhesion (the yellow circle shows the attached platelets). The similar results are repeated in three independent experiments (a, b, g). Data were presented as mean ± SD (n = 3 independent samples) (c, e, f).

Back to article page