Table 1 Comparison of RTP performance among different host−guest systems

From: Building bridges through dynamic coupling for organic phosphorescence

Sample

System

ΦP (%)a

τP (ms)

PY−PMMA

Polymer

/b

178c

PY−β-estradiol

Amorphous steroid

0.002

134

PY−BrCzA

Dynamic coupling

5.9

104

PY−CzBP

0.8

433

PY−BPCzA

1.1

414

PY-d10−PMMA

Polymer

0.01

98

PY-d10β-estradiol

Amorphous steroid

0.02

1536

PY-d10−BrCzA

Dynamic coupling

9.8

216

PY-d10−CzBP

2.7

2447

PY-d10−BPCzA

3.3

2268

  1. aΦP was calculated by the phosphorescence component in the photoluminescence spectra. If phosphorescence was too weak to be distinguished from fluorescence in the photoluminescence spectra, ΦP was determined based on phosphorescence component associated with relevant lifetimes.
  2. bNo phosphorescence was detected at room temperature.
  3. cMeasured at 77 K.