Table 1 Average breakdown potential and localized damage size distribution in the recrystallized and AM materials

From: Metastable cellular structures govern localized corrosion damage development in additive manufactured stainless steel

Material

Breakdown potential (vs. Ag/AgCl)

Average pit size

Recrystallized

510.6 ± 14 mV

3.58 μm

AM

585.8 ± 34 mV

2.75 μm (67.6 μm, clusters)