Table 2 Accuracy of each symptom (A) for detecting OAD and (B) for detecting asthma in patients who have OAD

From: Peak flow meter with a questionnaire and mini-spirometer to help detect asthma and COPD in real-life clinical practice: a cross-sectional study

Symptom

Sensitivity, %

Specificity, %

Positive predictive value, %

Negative predictive value, %

A Accuracy for detecting OAD

 Breathlessness (mMRC grade ≥ 1)

97.30

75.61

93.51

88.57

 Breathlessness > 6 months

94.59

78.05

93.96

80.00

 Cough

93.24

78.05

93.88

76.19

 Cough > 6 months

89.86

82.93

95.00

69.39

 Cough with expectoration

42.57

85.37

91.30

29.17

 Wheeze

83.11

92.68

97.62

60.32

B Accuracy for detecting asthma in patients who have OAD

 Wheeze

89.57

39.39

83.74

52.00

 Intermittent asymptomatic period

92.17

87.88

96.36

76.32

 Smoker

85.22

75.76

92.45

59.52

 Pack years < 10 years

90.43

75.76

92.86

69.44

 Family history of atopy

53.91

78.79

89.86

32.91

 Current age < 40 years

28.70

90.91

91.67

26.79

 Age of onset of breathlessness < 40 years

66.09

87.88

95.00

42.65

 Age of onset of cough < 40 years

68.70

87.88

95.18

44.62