Table 1 Change of membrane resistance before and after continuous reverse electrodialysis operation. The values with standard deviations were measured in triplicate at least.
Ω·cm2 | Flat with spacer | Pattern | ||
|---|---|---|---|---|
Pristine | Fouled | Pristine | Fouled | |
CEM | 0.49 ± 0.07 | 0.54 ± 0.03 | 0.83 ± 0.04 | 0.87 ± 0.04 |
AEM | 0.55 ± 0.02 | 0.67 ± 0.03 | 0.97 ± 0.08 | 1.05 ± 0.03 |