Table 2 Metric values resulting from the simulation scenarios
From: Optimization of valve switch control for contamination detection in water distribution network
| Â | Initial | IPBGOA | GOA | GA | DE | GWO | PSO |
\({Cov}\) (%) | 59.37 | 78.12 | 68.75 | 56.25 | 59.37 | 71.87 | 75 |
\(\bar{t}\) (h) | 12.3 | 6.3 | 8.6 | 10.5 | 10.8 | 7.75 | 7 |
\(\bar{I}\) (m3) | 14,816.73 | 2345.657 | 3062.364 | 3273.245 | 3571.942 | 2731.242 | 2507.868 |
\(\overline{{Hs}}\) (m) | Â | 98 | 109 | 93 | 73 | 79 | 85 |