Extended Data Fig. 7: Semi-preparative HPLC chromatogram from purification of [18F]FEDV with standard coinjection to confirm product identity. | Nature Biomedical Engineering

Extended Data Fig. 7: Semi-preparative HPLC chromatogram from purification of [18F]FEDV with standard coinjection to confirm product identity.

From: A positron emission tomography tracer for the imaging of oxidative stress in the central nervous system

Extended Data Fig. 7

(6.3 – 7 min). Progress was monitored by UV absorbance at 254 nm (red channel), 210 nm (purple channel), and radioactivity (green channel). HPLC column: Synergi Hydro-RP C18 column (10 μm, 250 × 10 mm, 80 Å) (Phenomenex, Torrance, CA) under isocratic flow of a mobile phase consisting of 35:65 ethanol:acetate buffer (0.2 M acetic acid/0.05 M sodium acetate) at 4.7 mL/min.

Back to article page