Extended Data Fig. 5: Retrieval of partial-wave amplitudes and phases from the measured photoelectron interferogram using global fitting.
From: Attosecond circular-dichroism chronoscopy of electron vortices

(a, b), Measured time-resolved photoelectron angular distributions of SB12 in co-rotating and counter-rotating geometries, which are the enlarged plots of Fig. 1f,g, respectively. (c, d), Reconstructed photoelectron interferograms in the two geometries using global fitting of the three-wave interference model based on the p+ ground state.