Extended Data Table 1 Detector configurations

From: Limits on the luminance of dark matter from xenon recoil data

  1. Basic detector configurations of the commissioning data sets, with \(\langle {\tau }_{e}\rangle ,d{t}_{\max }\), PDE, EEE, and SEGb representing the average electron lifetime, maximum drift time, photon detection efficiency, electron extraction efficiency, and single electron gain from the bottom PMT array (with a total-to-bottom ratio of 4.2), respectively.