Table 3 Column description of the protocol codes file.
Field | Description |
---|---|
Protocol code | ID corresponding to the one contained in the “LFMC data” sheet |
Time range for sampling | Time range of sampling. |
New and old leaves combined | Whether the Fuel Moisture Content value is a combination of current and previous year leaves. |
Weighing procedure | 1 if the fresh samples were weighed on the field; 2 if the fresh samples were weighed in the lab. |
Weighing device accuracy (g) | Accuracy (g) of the weighing device used. |
Material for transportation | Material or equipment used to seal the samples brought to the laboratory. |
Drying device | 1 if oven; 2 if microwave |
Drying time (h) | Duration (in hours) of the drying procedure of the sample. |
Drying temperature (°C) | Temperature in Celsius degrees of the drying procedure. |
Observations | Further comments and information regarding the protocol used. |