Table 2 Summary of the in-soil instrument’s specifications.
Variable (code) | Instrument | Qty per bay | Range of measurement | Uncertainty | Resolution | Additional information |
---|---|---|---|---|---|---|
Soil heat flux (SHF1, SHF1sc) | Campbell Scientific (Hukseflux) HFP-1 | 12 | −2000 Wm−2 to 2000 Wm−2 | • Temperature dependence <0.1%/°C • Thermal conductivity dependence 7%/(W/(mK)) • Non-stability <1%/yr • Factory calibration uncertainty <3% | <0.1 Wm−2 | Thermopile. At 5 cm depth. |
Campbell Scientific (Hukseflux) HFP-1SC | 12 | |||||
Soil temperature (ST) | Campbell Scientific TCAV | 12 | −40 °C to 50 °C | Not reported | 0.1 °C | Thermocouple. At 5 cm depth. |
Volumetric water content (VWC) | Decagon 5TM | 12 | 0% to 50% | <2% (VWC) after soil specific calibration. | 0.08% (VWC) | Apparent dielectric permittivity (ADP). At 5 cm depth. |