Table 2 Summary of the in-soil instrument’s specifications.

From: Highly sampled measurements in a controlled atmosphere at the Biosphere 2 Landscape Evolution Observatory

Variable (code)

Instrument

Qty per bay

Range of measurement

Uncertainty

Resolution

Additional information

Soil heat flux

(SHF1, SHF1sc)

Campbell Scientific (Hukseflux) HFP-1

12

−2000 Wm−2 to

2000 Wm−2

• Temperature dependence <0.1%/°C

• Thermal conductivity dependence 7%/(W/(mK))

• Non-stability <1%/yr

• Factory calibration uncertainty <3%

<0.1 Wm−2

Thermopile.

At 5 cm depth.

Campbell Scientific (Hukseflux) HFP-1SC

12

Soil temperature (ST)

Campbell Scientific TCAV

12

−40 °C

to

50 °C

Not reported

0.1 °C

Thermocouple.

At 5 cm depth.

Volumetric water content (VWC)

Decagon 5TM

12

0%

to

50%

<2% (VWC) after soil specific calibration.

0.08% (VWC)

Apparent dielectric permittivity (ADP).

At 5 cm depth.