Table 1 Overview of the imaging statistics of the CT scans within our collection, including parameters and steps used during pre-processing.
From: Synthetic skull bone defects for automatic patient-specific craniofacial implant design
Patient | Number of Slices | Inplane Resolution (mm2) | Slice Thickness (mm) | Cropping (yes/no) | Threshold (HU) | Manual post-processing (yes/no) | |
---|---|---|---|---|---|---|---|
whole | cropped | ||||||
1 | 490 | 87 | 0.98 × 0.98 | 2.00 | yes | 150 | yes (artifact removal) |
2 | 244 | 124 | 0.98 × 0.98 | 1.25 | yes | 150 | yes (hole filling) |
3 | 350 | 148 | 0.59 × 0.59 | 1.00 | yes | 200 | yes (smoothing) |
4 | 327 | 51 | 0.98 × 0.98 | 3.27 | yes | 150 | yes (hole filling) |
5 | 286 | 129 | 0.98 × 0.98 | 1.25 | yes | 150 | yes (hole filling) |
6 | 227 | 123 | 0.98 × 0.98 | 1.25 | yes | 150 | no |
7 | 268 | 144 | 0.59 × 0.59 | 1.00 | yes | 150 | yes (hole filling) |
8 | 201 | 135 | 0.98 × 0.98 | 1.25 | yes | 200 | yes (smoothing) |
9 | 175 | 83 | 0.98 × 0.98 | 2.00 | yes | 150 | no |
10 | 327 | 49 | 0.98 × 0.98 | 3.27 | yes | 150 | no |
11 | 47 | 47 | 0.98 × 0.98 | 3.27 | no | 150 | yes (hole filling) |
12 | 242 | 149 | 0.41 × 0.41 | 1.00 | yes | 150 | yes (smoothing) |
13 | 160 | 124 | 0.43 × 0.43 | 1.00 | yes | 150 | yes (hole filling) |
14 | 287 | 160 | 0.59 × 0.59 | 1.00 | yes | 200 | yes (smoothing) |
15 | 231 | 161 | 0.46 × 0.46 | 1.00 | yes | 200 | yes (smoothing) |
16 | 147 | 101 | 0.50 × 0.50 | 1.50 | yes | 150 | yes (hole filling) |
17 | 161 | 154 | 0.43 × 0.43 | 1.00 | yes | 150 | yes (hole filling) |
18 | 318 | 210 | 0.49 × 0.49 | 0.75 | yes | 150 | yes (hole filling/artifact removal) |
19 | 136 | 78 | 0.42 × 0.42 | 2.00 | yes | 150 | yes (smoothing) |
20 | 232 | 159 | 0.51 × 0.51 | 1.00 | yes | 150 | yes (smoothing) |
21 | 168 | 112 | 0.46 × 0.46 | 1.50 | yes | 200 | no |
22 | 200 | 155 | 0.46 × 0.46 | 1.00 | yes | 150 | no |
23 | 110 | 77 | 0.45 × 0.45 | 2.00 | yes | 150 | yes (hole filling) |
24 | 298 | 195 | 0.47 × 0.47 | 0.75 | yes | 150 | yes (smoothing) |