Table 5 Measurement variables and instrumentation.

From: Dataset of low global warming potential refrigerant refrigeration system for fault detection and diagnostics

Measured Variable

Instruments

Range

Accuracy

Power

MT 1st compressor power

Watt transducer

0–80,000 W

±5% of reading

MT 2nd compressor power

0–80,000 W

MT 3rd compressor power

0–80,000 W

LT 1st compressor power

0–8,000 W

LT 2nd compressor power

0–8,000 W

Mass Flow Rate

MT evaporator mass flow rate

Coriolis Mass flow meter

 

±5% of reading

LT evaporator mass flow rate

0–10 kg/min

Flash tank bypass mass flow rate

 

Temperature

MT display case suction temperature

Thermocouple

−270- 400 °C

Greater of 1.0 °C or 0.75% for 0 to 350 °C)

LT display case suction temperature

Flash tank vapor outlet temperature

Gas cooler inlet/outlet temperature

MT compressor rack inlet/outlet temperature

LT compressor rack inlet/outlet temperature

MT 1st compressor suc./dis. temperature

MT 2nd compressor suc./dis. temperature

MT 3rd compressor suc./dis. temperature

LT 1st compressor suc. /dis. temperature

LT 2nd compressor suc./dis. temperature

Pressure

MT display case suction pressure

Pressure transducer

0–14 Mpa

±0.25% full scale

LT display case suction pressure

0–7 Mpa

Flash tank vapor outlet pressure

0–14 Mpa

Gas cooler inlet/outlet pressure

0–14 Mpa

MT compressor rack inlet/outlet pressure

0–14 Mpa

LT compressor rack inlet pressure

0–7 Mpa

LT compressor rack outlet pressure

0–14 Mpa