Table 3 Specification of instruments.

From: Dataset of ultralow temperature refrigeration for COVID 19 vaccine distribution solution

Instruments

Measurement

Measurement Range

Accuracy

Type-T thermocouple

Temperature distribution of container and packages, Supply and return air temperature of refrigeration system

Element temp range is −195 °C(−320°F) to 371 °C(700 °F), insulation rated to 221 F

±0.5 °C (±0.9 °F)

CO2 sensor, NDIR Non-Dispersive InfraRed, pass through type, 5VDC input

CO2 level inside of container

1 to 4.7 VDC for 0 to 30% Vol. CO2 Concentration linear

±[0.2%vol. CO2 ± 3% of measured value] ± [20 mV ± 2% of measured volts]*8.11%/V

Figaro O2 sensor, Electrochemical Fuel Cell, pass through type, Amplified with 5 VDC input

O2 level inside of container

0.144 to Span Voltage (Calibration 20.8% Vol., value)

+/− 1%

Omega Differential Pressure Transmitter, Diaphragm Differential Pressure, 12 to 36 VDC input

pressure difference between inside and outside of refrigeration container unit

1 to 5 VDC for −10 to 10 IWG (Inch Water Gauge)

As good as calibrated 0.05%

Scale (Mechanical)

weight

0–31.75 kg (70 lbs)

0.567 kg (1/8 lbs)