Table 1 Comparison of SHDB-AF to previous works.

From: SHDB-AF: a Japanese Holter ECG database of atrial fibrillation

Dataset

Origin

N

Record length

Device

Sampling rate

Individual clinical detail beyond age and sex

AF annotation

SHDB-AF (this work)

Japan

128

24 hours

2-channel Holter

125

Height, weight, medication, AF subtypes, medication, ablation, echocardiography parameters, pacemaker, comorbidities

YES

MIT-BIH Arrhythmia Database

USA

48

30 minutes

2-channel Holter

360

medication

No

MIH-BIH AFDB

USA

23

10 hours

2-channel Holter

250

No

YES

LTAFDB

USA

84

24 hours

2-channel Holter

128

No

YES

IRIDIA-AF

Belgium

167

~20–96 hours

2-channel Holter

200

No

YES

Icentia11k

Canada

11,000

1–2 weeks

Single lead ECG patch

250

No

YES

CPSC2021

China

47

varied

12-lead Holter or 3-lead wearable ECG monitoring devices

200

No

No

  1. While MIT-BIH Arrhythmia Database, IRIDIA-AF provide basic clinical information such as sex and age of patients, to the best of our knowledge, SHDB-AF is the first to provide detailed clinical information such as height, weight, AF subtype, history of ablation, pacemaker, echocardiography parameters, and comorbidities.