Table 3 Screening protocol at 25 °C.
From: High-power lithium-ion battery characterization dataset for stochastic battery modeling
Phase 1: Cell Screening | |||
---|---|---|---|
Step | Action | Exit Condition | Notes |
1 | 1C CC charge | Vcell ≥ 4.2 V | |
2 | CV hold at 4.2 V | Icell ≤ 50 mA | |
3 | Rest | 30 mins | |
4 | 1C CC discharge | Vcell ≤ 2.5 V | |
5 | Rest | 30 mins | |
6 | 1C CC charge | Vcell ≥ 4.2 V | |
7 | CV hold at 4.2 V | Icell ≤ 50 mA | |
8 | Rest | 1 h | |
9 | C/3 CC discharge | Vcell ≤ 4 V | Corresponds to an SoC of 80% |
10 | 1C CC discharge | 5 s | |
11 | C/3 CC discharge | Vcell ≤ 3.7 V | Corresponds to an SoC of 50% |
12 | 1C CC discharge | 5 s | |
13 | C/3 CC discharge | Vcell ≤ 3.4 V | Corresponds to an SoC of 20% |
14 | 1C CC discharge | 5 s | |
15 | C/3 CC discharge | Vcell ≤ 2.5 V | |
16 | Rest | 1 h |