Table 1 Simulated Bone Material Properties.

From: Implantable strain sensor to monitor fracture healing with standard radiography

 

Longitudinal Tensile

Transverse Tensile

Compressive

Strength (MPa)

Modulus (GPa)

Strength (MPa)

Modulus (GPa)

Strength (MPa)

Modulus (GPa)

Cortical

106

16

93

10

157

16.7

Cancellous

6

0.155

  1. The table shows the material properties used in the FEA presented in this paper. These material properties are provided by Sawbones® and are based on ASTM D-638 and D-695.