Table 2 Fitted Raman spectra of the worn cast iron surfaces: Position and FWHM of D and G peaks.

From: Tribochemistry of adaptive integrated interfaces at boundary lubricated contacts

Sample

D peak (cm−1)

FWHM of D peak (cm−1)

G peak (cm−1)

FWHM of G peak (cm−1)

CrN + GLC-1h

1388.52

142.87

1598.72

135.16

CrN + GLC-2h

1360.31

84.59

1600.23

138.83

CrN + GLC-4h

1341.17

131.97

1604.87

73.87

CrN + GLC-8h

1356.13

169.32

1598.20

87.52