Table 2 Fitted Raman spectra of the worn cast iron surfaces: Position and FWHM of D and G peaks.
From: Tribochemistry of adaptive integrated interfaces at boundary lubricated contacts
Sample | D peak (cm−1) | FWHM of D peak (cm−1) | G peak (cm−1) | FWHM of G peak (cm−1) |
---|---|---|---|---|
CrN + GLC-1h | 1388.52 | 142.87 | 1598.72 | 135.16 |
CrN + GLC-2h | 1360.31 | 84.59 | 1600.23 | 138.83 |
CrN + GLC-4h | 1341.17 | 131.97 | 1604.87 | 73.87 |
CrN + GLC-8h | 1356.13 | 169.32 | 1598.20 | 87.52 |