Table 1 An overview on the accuracy of alignment for the images shown in Figs 36.

From: Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision

Figure

3 A

3B

3 C

4

5

6

Number of beads picked for LOOCV

4*

20

20

Accuracy of alignment (LOOCV)

333 nm

112 nm

64 nm

Number of structures analyzed for uranyl acetate based alignment

10

10

10

10

10

10

Accuracy of alignment, based on uranyl acetate

26 nm

30 nm

25 nm

21 nm

38 nm

36 nm

Alignment of FP to uranyl acetate (FP variant in brackets)

12 nm (GFP)

24 nm (RFP)

50 nm (RFP)

Overall alignment accuracy

26 nm

30 nm

25 nm

24 nm

45 nm

62 nm

  1. *Only two beads are shown in the field of view, for full image, please refer to Supplementary Fig. S2. For further details on the alignment accuracy, please refer to Supplementary Tables S1S4, as well as Supplementary Figs S2S8 & S10S15.