Table 4 Description of tested solutions. All suppliers confirmed the use of the moist heat method but some did not provide their protocol: A: Not communicated, B: Not communicated, C: F0 ≥ 11, D: F0 ≥ 15 (estimated between at 42 and 45), D’: F0 ≥ 15 (estimated at 20), E: F0 = 15.

From: Factors Generating Glucose Degradation Products In Sterile Glucose Solutions For Infusion: Statistical Relevance Determination Of Their Impacts

Supplier

N

Conc (%)

Volume (ml)

Type of Container

Type of container material

Time-lapse since manufacture (months)

A

20

2.5–5–10

50–100–250–500–1000

Bag

PE/PA/PP

7–9–10–12–14–15–16–17–20–31–32–33–34–51

B

15

2.5–5–10–30–50–70

50–100–250–500–1000

Flask – Vial

PE - Glass

4–5–6–7–8–11–17–18–25–29–36

C

9

5–10

250–500

Flask – Bag

PE – PP

15–16–18–20–34–43–44

D

3

10

250

Bag

PP

13–19

D’

16

5–10–15–30

125–250–500–1000

Vial

Glass

10–13–15–18–20–23–25–28–31–33–46–50–54–58–61

E

21

2.5–5–10–15–20–30–50

50–100–250–500–1000

Bag

PE/PP - PVC

11–15–16–17–18–20–23–26–29–31–37–41–56