Figure 5
From: Correlation between tunability and anisotropy in magnetoelectric voltage tunable inductor (VTI)

Comparison of theory and experiment. The theory is fitted to reproduce linear tunability of Regime I (red line) and Regime II (blue line) of experimental data (black circles). Deviation of experimental data from theory is attributed to non-uniformities in magnetic domains and material microstructures.