Table 1 Gradient profile for the liquid chromatographic separation samples collected from in vitro amide hydrolysis assays. For positive mode ESI mass spectrometric acquisitions, mobile phase A = 10 mM ammonium formate containing 0.1% (v/v) formic acid; mobile phase B = acetonitrile. For negative mode ESI mass spectrometric acquisitions, mobile phase A = 10 mM ammonium acetate; mobile phase B = acetonitrile.
From: Metabolic Hydrolysis of Aromatic Amides in Selected Rat, Minipig, and Human In Vitro Systems
Time (min) | % Mobile Phase A | % Mobile Phase B | Gradient Profile |
---|---|---|---|
0.00 | 100 | 0 | 6 |
0.05 | 100 | 0 | 6 |
1.00 | 5 | 95 | 5 |
1.40 | 100 | 0 | 11 |
1.80 | 100 | 0 | 6 |