Figure 3 | Scientific Reports

Figure 3

From: 3D-printed components for quantum devices

Figure 3

Plot of the calculated (finite-element) versus measured magnetic field magnitude along each axial direction. Dotted lines here show ideal 2:−1:−1 ratio between strong and weak axes. Along all three optical axes, the linear field region extends over the full cylinder aperture, ensuring optimal laser cooling.