Table 2 Full shape of the crystalline lens biometric parameters for each patient (mean ± standard deviation across measurements).

From: Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas

 

LT (mm)

RAL (mm)

RPL (mm)

VOL (mm3)

DIA (mm)

LSA (mm2)

EPP (mm)

EPP/LT

LSA/VOL (mm−1)

S#1 (OD)

4.62 ± 0.005

7.14 ± 0.21

5.57 ± 0.07

178 ± 3.7

8.83 ± 0.12

165 ± 3.7

2.16 ± 0.016

0.467

0.927

S#2 (OS)

4.35 ± 0.005

8.94 ± 0.49

5.80 ± 0.14

177 ± 5.0

9.00 ± 0.13

168 ± 4.1

1.92 ± 0.025

0.441

0.949

S#3 (OD)

5.67 ± 0.001

7.77 ± 0.18

5.46 ± 0.20

264 ± 2.5

9.51 ± 0.10

209 ± 1.0

2.63 ± 0.003

0.463

0.792

S#3 (OS)

5.61 ± 0.002

7.62 ± 0.06

5.05 ± 0.02

246 ± 1.6

9.36 ± 0.05

198 ± 1.0

2.57 ± 0.007

0.457

0.805

S#4 (OD)

4.79 ± 0.019

9.70 ± 0.21

5.84 ± 0.12

218 ± 0.4

9.54 ± 0.03

191 ± 0.8

2.10 ± 0.020

0.438

0.876

S#4 (OS)

4.75 ± 0.01

9.53 ± 0.19

5.90 ± 0.03

224 ± 2.5

9.77 ± 0.08

195 ± 1.5

2.14 ± 0.021

0.450

0.871

S#5 (OD)

4.41 ± 0.003

9.15 ± 0.56

5.41 ± 0.17

176 ± 5.1

8.92 ± 0.17

166 ± 4.2

1.94 ± 0.041

0.440

0.943

S#5 (OS)

4.55 ± 0.003

8.75 ± 0.23

5.88 ± 0.002

199 ± 0.4

9.26 ± 0.05

182 ± 1.3

2.05 ± 0.004

0.451

0.915

S#6 (OD)

4.18 ± 0.004

11.70 ± 0.63

6.54 ± 0.23

193 ± 4.5

9.60 ± 0.11

185 ± 3.5

1.84 ± 0.026

0.442

0.958

S#6 (OS)

4.17 ± 0.001

11.25 ± 0.70

6.37 ± 0.17

186 ± 5.0

9.43 ± 0.15

178 ± 1.8

1.84 ± 0.002

0.440

0.957

S#7 (OD)

5.23 ± 0.005

8.75 ± 0.06

5.43 ± 0.02

237 ± 4.2

9.60 ± 0.03

198 ± 2.2

2.32 ± 0.001

0.444

0.835

S#7 (OS)

4.78 ± 0.005

8.45 ± 0.29

5.74 ± 0.12

197 ± 4.4

9.09 ± 0.10

176 ± 3.2

2.20 ± 0.008

0.459

0.893

  1. LT = lens thickness; RAL = crystalline lens anterior radius of curvature; RPL = crystalline lens posterior radius of curvature; VOL = lens volume; DIA = lens equatorial diameter; LSA = lens surface area; EPP = equatorial plane position.