Table 4 Postoperative refraction estimation: mean arithmetic refractive error (MRE), mean absolute refractive error (MARE), refractive error (RE) range, and p values of the statistical tests performed, for the different methods.
Method | MRE ± SD (D) | P value (t-test) | MARE ± SD (D) | RE range (D) | P value (multiple test, Bonferroni correction) |
---|---|---|---|---|---|
Proposed | −0.09 ± 0.37 | 0.41 | 0.24 ± 0.29 | −1.08 to 0.33 | — |
Olsen Constant | −0.04 ± 0.46 | 0.75 | 0.36 ± 0.27 | −0.95 to 0.63 | 1 |
Olsen C optimized | −0.08 ± 0.46 | 0.54 | 0.37 ± 0.26 | −1.00 to 0.58 | 1 |
SRK/T | 0.20 ± 0.53 | 0.23 | 0.47 ± 0.28 | −0.73 to 0.93 | 0.16 |
SRK/T A optimized | −0.08 ± 0.53 | 0.61 | 0.41 ± 0.31 | −1.20 to 0.62 | 1 |
Intersection approach | 0.03 ± 0.44 | 0.81 | 0.37 ± 0.23 | −0.83 to 0.53 | 0.12 |