Table 2 Confusion matrix and performance metrics in setup I (class scheme).

From: A Personalized Arrhythmia Monitoring Platform

 

Predicted Labels

Total

S E

(%)

P P

(%)

F S

(%)

 

N

L

R

A

V

P

a

!

F

x

j

f

E

J

e

Q

Ground Truth

N

61910

130

0

1193

311

0

61

23

57

0

33

27

0

0

11

8

63764

97.09

99.11

98.09

L

122

5051

0

0

74

0

0

0

0

0

0

0

0

0

0

0

5247

96.26

94.02

95.13

R

157

0

4461

71

19

0

0

0

0

0

0

0

0

8

0

0

4716

94.59

100

97.22

A

32

23

0

1487

14

0

0

4

95

0

0

0

0

0

0

0

1655

89.85

53.78

67.28

V

86

15

0

0

4369

0

0

79

71

0

0

14

0

0

0

0

4634

94.28

90.59

92.4

P

23

109

0

0

0

4357

0

0

0

0

0

77

0

0

0

0

4566

95.42

99.89

97.6

a

13

0

0

7

3

0

52

0

0

0

0

0

0

0

0

0

75

69.33

46.02

55.32

!

14

32

0

0

19

0

0

171

0

0

0

0

0

0

0

0

236

72.46

60.64

66.02

F

41

0

0

0

11

0

0

0

349

0

0

0

0

0

0

0

401

87.03

61.01

71.74

x

11

0

0

3

0

0

0

5

0

77

0

0

0

0

0

0

96

80.2

100

88.34

j

14

0

0

0

0

0

0

0

0

0

96

0

0

4

0

0

114

84.21

74.42

79.01

f

23

11

0

0

0

4

0

0

0

0

0

453

0

0

0

0

491

92.26

78.92

85.07

E

8

0

0

0

0

0

0

0

0

0

0

0

45

0

0

0

53

84.91

100

91.84

J

3

0

0

4

2

0

0

0

0

0

0

0

0

32

0

0

41

78.05

72.73

75.29

e

4

1

0

0

0

1

0

0

0

0

0

0

0

0

2

0

8

25

15.38

19.05

Q

6

0

0

0

1

0

0

0

0

0

0

3

0

0

0

6

16

37.5

42.86

37.5

 

Total

62467

5372

4461

2765

4823

4362

113

282

572

77

129

574

45

44

13

14

86113

96.29

96.29

76.06