Figure 4 | Scientific Reports

Figure 4

From: Nanoparticle architecture preserves magnetic properties during coating to enable robust multi-modal functionality

Figure 4

Imaging MRI and CT. (a) MR imaging contrast of JHU MIONs (1), Si-MIONs (2) and AuSi-MIONs (3). Imaging of gel phantoms over a range of 0–80 μg/ml (0–1.4 mM) based on iron content, showing T2 effect as iron concentration increases (top). T2 relaxation (ms) calculated from spin-echo MR imaging of phantoms (bottom). Inset shows concentration (mM) versus 1/T2, the slope of which gives transverse relaxivity (R2) in units of mM−1 s−1. (b) Signal intensity from MION phantoms over a range of 0–7 mg/ml (based on iron content) demonstrating CT contrast with gold (top). CT contrast, measured in Hounsfield units (HU), was calculated for each sample and were plotted versus iron concentration (bottom).

Back to article page