Table 3 Distances between reference points with differences before and after RapidNAM-molding therapy.

From: A semi-automated virtual workflow solution for the design and production of intraoral molding plates using additive manufacturing: the first clinical results of a pilot-study

DISTANCE

MIN.

1ST QUARTILE

MEDIAN

MEAN

3RD QUARTILE

MAX.

SD

A - MT IMPRESSION 1

25.5

27.2

27.8

28.7

29.7

34.1

3.0

A - MT IMPRESSION 2

25.4

26.0

27.7

27.1

27.9

28.7

1.4

A - MT DIFFERENCE

−6.6

−4.2

−1.1

−1.6

0.6

3.2

3.7

L - L’ IMPRESSION 1

27.5

30.5

31.7

31.5

33.3

34.3

2.5

L - L’ IMPRESSION 2

26.3

28.4

28.9

29.2

29.8

33.2

2.3

L - L’ DIFFERENCE

−4.8

−4.5

−4.3

−2.3

−2.1

5.7

4.1

SA - SA’ IMPRESSION 1

5.2

7.8

10.8

11.4

14.3

19.8

5.4

SA - SA’ IMPRESSION 2

2.6

3.2

3.8

5.1

6.9

9.4

2.8

SA - SA’ DIFFERENCE

−10.3

−8.7

−6.0

−6.4

−4.7

−2.0

3.1

T - T’ IMPRESSION 1

32.3

32.9

34.4

34.3

35.6

36.4

1.7

T - T’ IMPRESSION 2

33.8

35.2

35.8

35.8

36.7

37.3

1.3

T - T’ DIFFERENCE

−1.3

−0.8

1.0

1.5

3.7

5.0

2.7

SD - SD’ IMPRESSION 1

11.7

21.4

21.9

21.1

22.1

27.4

5.1

SD - SD’ IMPRESSION 2

16.9

20.0

21.0

20.7

22.5

22.9

2.2

SD - SD’ DIFFERENCE

−4.5

−1.9

−0.5

−0.3

0.5

5.2

3.3