Table 2 Momentum compaction of the beam dump line (R56), bunch duration at its entrance (σt,i), measured and simulated pulse energies in the 0.01–10 THz range. Pulse energies simulated without CSR are in italics. The error on the measured energy value is dominated by the signal RMS fluctuation.
From: Coherent THz Emission Enhanced by Coherent Synchrotron Radiation Wakefield
Configuration | R56 [mm] | σt,i [ps] | E [µJ] simul. | E [µJ] meas. |
---|---|---|---|---|
OS1 | 5 | 0.35 | 51 | 50 ± 4 |
OS2 | 19 | 0.35 | 80 | 77 ± 7 |
OS2 No CSR | 19 | 0.35 | 48 | |
CF1 | 37 | 0.35 | 34 | 33 ± 3 |
CF2 | 37 | 0.25 | 82 | 76 ± 7 |
CF2 No CSR | 37 | 0.25 | 66 |