Table 1 Estimated values of critical angle (see Fig. 7A) and threshold force for three surfaces.
From: A magnet-actuated biomimetic device for isolating biological entities in microwells
Surface | Critical angle (α) | Threshold force (µN) |
---|---|---|
Plain | 57.4° | ~3.80 |
Microwell-surface | 56.4° | ~3.76 |
Micropillar-surface | 41.5° | ~2.99 |