Table 2 EIS parameters and corrosion inhibition efficiencies obtained from fitting impedance spectra of C-steel in 0.5 M HCl at different concentrations of AEO7 at 20, 30, 40 and 50 °C using the electrical equivalent circuit shown in Fig. 4.

From: AEO7 Surfactant as an Eco-Friendly Corrosion Inhibitor for Carbon Steel in HCl solution

T (°C)

Cinh µmol L−1

Rct, Ω cm2

CPE

\(\theta \)

Corrosion IE%

Y0 µsn ohm−1 cm−2

Cdl, µF

n

20

Blank

43.1

257.0

119.7

0.855

20

128.2

211.7

82.57

0.793

0.664

66.4

30

169.8

194.5

76.85

0.786

0.746

74.6

35

253.0

161.4

69.31

0.791

0.830

83.0

40

341.6

105.95

59.49

0.852

0.874

87.4

30

Blank

30.8

381.8

218.7

0.889

20

90.42

314.1

202.2

0.890

0.660

66.0

30

114.2

260.4

156.8

0.874

0.730

73.0

35

164.5

236.8

103.6

0.797

0.813

81.23

40

211.5

149.2

64.25

0.804

0.854

85.4

40

Blank

24.27

425.0

252.7

0.898

20

64.8

405.7

231.0

0.866

0.625

62.5

30

89.0

390.3

185.7

0.819

0.727

72.7

35

112.2

377.0

141.9

0.764

0.786

78.6

40

145.8

331.4

124.6

0.756

0.833

83.3

50

Blank

18.5

606.5

295.6

0.862

20

49.27

554.2

254.1

0.822

0.622

62.2

30

59.32

543.7

217.4

0.789

0.688

68.8

35

69.72

515.7

187.7

0.890

0.734

73.4

40

90.42

492.8

155.0

0.729

0.795

79.5