Table 1 Exponents for power law distributions in Mg/Ho for strong and weak AE signals.
Parameter | MF value/Force integrated17 | Experimental (weak/strong) |
---|---|---|
ε (Energy) | 1.33/1.67 | 1.92 ± 0.12/1.40 ± 0.1 |
τ′ (Amplitude) | 1.67/2.33 | 2.44 ± 0.09/1.82 ± 0.08 |
α (Duration) | 2.0/3.0 | 3.0 ± 0.2/2.56 ± 0.2 |
x (Energy-Amplitude) | 2.0/2.0 | 1.7 ± 0.1/1.93 ± 0.1 |
χ(Amplitude-Duration) | 1.5/1.5 | 1.42 ± 0.02/1.95 ± 0.15 |