Table 6 The warning results of some landslide monitoring sites with “step-like” behavior.
Landslide | Step-like period | The largest rainfall criterion value /mm | Predictive Warning level | Actual displacement /mm | Displacement ratio/×10–5 | Percentage of total displacement /% |
---|---|---|---|---|---|---|
CJBL | 2007.6~2007.8 | 133.5 | Warning level 3 | 167.1 | 11.1 | 11.5 |
2012.6~2012.9 | 91.8 | Warning level 2 | 123.7 | 8.2 | 8.5 | |
2014.8~2014.9 | 133.1 | Warning level 3 | 701.8 | 46.8 | 48.3 | |
HNBL | 2007.6~2007.8 | 133.5 | Warning level 3 | 103.9 | 23.1 | 4.6 |
2009.5~2009.9 | 184.6 | Warning level 4 | 157.3 | 35.0 | 7.0 | |
2011.5~2011.8 | 157.7 | Warning level 4 | 82.4 | 18.3 | 3.7 | |
2012.5~2012.8 | 104.8 | Warning level 3 | 147.9 | 32.9 | 6.6 | |
XLTL | 2007.6~2007.8 | 133.5 | Warning level 3 | 325.5 | 27.1 | 29.5 |
2012.6~2012.9 | 91.8 | Warning level 2 | 147.1 | 12.3 | 13.3 |