Table 4 Parameters of Cine-MRI studies included.
Author, Year | Breath | Oriention | Number of slices | Sclice thickness (mm) | FOV (cm) | Matrix | Temporal resolution | Scan time |
---|---|---|---|---|---|---|---|---|
de Jonge 2018 | BH | Cor | 1 | 10 | 40 | 160 | 10 frames/s | 20 s |
Khalaf 2018 | FB | Cor | 1 | 10 | 1 s | 60 s | ||
Fuyuki 2017 | BH | Cor | 3 | 10 | 38 | 256 | 0.5 s | 16 s |
Bickelhaupt 2015 | BH | Cor | multiple | 3 | 14.4 | 68 | 60 s | |
Bickelhaupt 2015 | BH | Cor, Sag | multiple | 10 | 40 | 256 | 550 s | 40 s |
Bickelhaupt 2014 | BH | Cor | 15–25 | 10 | 40 | 256 | 550 s | 17 s/slice |
Ghobrial 2014 | Cor | 8 | 36–40 | 160–268 | 1–2 s | |||
Menys 2014 | BH FB | Cor | 6 slices in a volum | 30/volum | 42 | 1 volume/s | 20 s/slice 1 min FB | |
Bickelhaupt 2014 | FB | Cor | multiple | 10 | 48 | 256 | 250 ms | |
Menys 2013 | BH | Sag, Cor, Axi | multiple | 42 | 1 volume/s | |||
Ohkubo 2013 | BH | Cor | 3 | 10 | 38 | 256 | 0.5 s | 16 s |
Takahara 2011 | BH | Cor | 1 | 10 | 38 | 192 | 0.9 s | 20 s |
Takahara 2011 | BH | Cor | 1 | 10 | 38 | 192 | 0.98 s | 20 s |