Figure 3

Probing memory retention dynamics of a PVP-Ag network. (a) Changes in network conductance after applying a square pulse between two electrodes. Red line: a 5 V voltage pulse profile was used to activate the network and 10 mV to read current during network deactivation. Blue line: network conductance response time profile. (b) Typical deactivation profiles acquired during 100 s after applying square pulses, same parameters as in (a). (c) Simulated data using the same pulse profile as in (a) for a nanowire network generated on a 100 × 100 µm2 two-dimensional grid. Reading voltage was 0.1 mV in the simulated network, to account for the reduced size of the grid. The decay dynamics of two different junction resistance models, Continuous (or HP), pink line, and discrete (or Binary), blue line, is overlaid for comparison.