Figure 5

Stimulating training regimens modulates firing patterns in the frequency domain. a. Fifteen second representation of spontaneous voltage recording from NS:NS, NS:S, S:NS and S:S samples for D25. b. Smoothened (3 point moving average) and normalized (AUC) power spectra was calculated for contiguous 10 s windows across the 4 min of spontaneous recording NS:NS, NS:S, S:NS and S:S. Resulting matrices were averaged across samples. c. Bar graph for the sum of power spectral density magnitude from (b) across the spontaneous recording time between 0.1 Hz and 1 Hz (n = 3; error bar represents SEM, *p < 0.05, ANOVA with Tukey post-hoc test).