Table 3 The AUC, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the 6M50LSG scoring system in the score generator, internal validation, and external validation groups.
Score > 1 | ||||||
|---|---|---|---|---|---|---|
Score generator | Internal validation | External validation | ||||
Sensitivity | 86.30% | (76.25–93.23% | 92% | (73.97–99.02%) | 90.53% | (86.77–93.15%) |
Specificity | 91.84% | (80.40–97.73%) | 92.31% | (63.97–99.81%) | 68.57% | (59.51–76.01%) |
PPV | 94.03% | (85.98–97.59%) | 95.83% | (77.71–99.35%) | 88.59% | (85.78–90.90%) |
NPV | 81.82% | (71.55–88.95%) | 85.71% | (61.14–95.81%) | 72.00% | (64.77–78.25%) |
AUC | 0.923 | 0.975 | 0.802 | |||